Get a quote Warranty infomation Go to home page Where to order
Request a catalog Send an Email

 

antennas
Comb Generators
Comb Generators
Near Field Probes
Preamplifiers Near Field Probes
poweramplfiers
Spectrum analyzer
Test System Spectrum analyzer
lisn.htm
lisn.htm Coupling Decoupling Network
Absorbing Clamps
Test Accessories
Turntables
Antenna Mast & Tripod
Telecom - Part 68
Product safety accessories

 

 

CDN FOR EMI CONDUCTED IMMUNINITY TESTING

Coupling / Decoupling Networks (CDN)

Coupling / Decoupling Networks (CDN) are for testing from 150 kHz - 80 MHz according to the EN 61000-4-6 standard for immunity to conducted disturbance induced by radio frequency fields. As the name implies the CDNs has both coupling and decoupling networks. The coupling network delivers injected RF common mode current disturbance signals through the various conductors to the equipment under test (EUT). The decoupling networks are used insure that the disturbing signals injected on the signal or power line of the EUT by the coupling networks does not interfere with any the auxiliary equipment (AE) connected to the EUT. Each CDN contains integrated direct capacitive coupling along with the high impedance choke for inductive decoupling.

The disturbing signal can be injected on signal lines and power line of an EUT by using the appropriate CDN described below. The CDN setup must be calibrated to establish the drive table. Please use the appropriate calibration components for the CDN. For each CDN you will need

  • Calibration adapters
  • 2 units of the 150 Ohm to 50 Ohm adapter
  • 1 unit of the 50 Ohm Terminator
  • Optional Ground plane

M series CDNs for powerline conductors

The M series CDNs are for injecting common mode current disturbance on to the powerline conductor of the equipment under test. The CDN to be used is determined by the number of wires in the conductor. The standard M series CDNs have a current rating of 25 Amps.

Model

# of wires
in the power cord

Coupling Point

Application

CDN-M125 1 Each wire Single Line
CDN-M225 2 Each wire Single Phase + Neutral
CDN-M325 3 Each wire Single Phase + Netural + Earth
CDN-M425 4 Each wire Three Phase + Earth
CDN-M525 5 Each wire Three Phase + Neutral + Earth

C series CDNs for shielded coax cables

The C series CDNs are for injecting disturbing signals on to 50 Ohm (CDN-C50) and 75 Ohm (CDN-C75) shielded coax cables. These CDN have BNC connectors for EUT and AE connections.

Model Cable Impedance Coupling Point
CDN-C50 50 Shield
CDN-C75 75 Shield

AF series CDNs for unshielded signal cables

The AF series CDNs are for unshielded cables with single or multiple conductors carrying low current. AF series CDNs are supplied with a professional audio connectors.

Model # wires in the cable
Coupling Point
CDN-AF2 2 Each wire
CDN-AF4 4 Each wire
CDN-AF8 8 Each wire

S Series CDNs for shielded signal cables

The S series CDNs are for shielded cables with single or multiple conductors. These CDNs are supplied with proffessional audio, D type and Centronics connectors.

Model # wires in the cable
Coupling Point
CDN-S1 1 Shield
CDN-S2 2 Shield
CDN-S4 4 Shield
CDN-S9 9 Shield
CDN-S15 15 Shield
CDN-S25 25 Shield
CDN-S36 36 Shield
CDN-S50 50 Shield

T series CDNs for unshielded balanced pairs

The T series CDNs are for cables with unshielded balanced conductor pairs typically found in ISDN, DSL and 10/100 baset-T data transfer applications.

Model Unbalanced Conductor Pairs
Coupling Point
CDN-T2 2 Each balanced pair
CDN-T4 4 Each balanced pair
CDN-T8 8 Each balanced pair
Last Updated: 12/12/2007
Warranty infomation
webmaster Site Map
industry links quality Survey

114 Olinda Drive, Brea, California 92823, U.S.A
Copyright Com-Power Corporation 2004
The information presented on this web site is intended to be accurate and authoritative information on the subject matter covered. It is distributed with the understanding Com-Power assumes no liability whatsoever in connection with its use.