CG & CGO SERIES COMB GENERATORS FOR EMI RADIATED EMI TESTING

EMI test labs must insure repeatable electromagnetic Interference (EMI) measurements. This is often accomplished by calibrating the EMI test site at regular intervals using published test methods. These methods although accurate, are elaborate and time consuming and are not practical to be performed before each EMI test. Com-Power CG orCGO series Comb Generator is a solution to this problem. The Comb Generator is a reference radiating EMI source for quick radiated EMI site verification. It can be used identify potential measurement errors that can be cause by malfunctioning instrumentation or changes to the test setup.

The Comb Generator is self contained radiating signal source. It produces all the harmonics of the frequency determined by step size up to it's maximum range of operation. The output level of the Comb Generator is fixed and has minimum variation. The Comb Generators are battery operated and have no interconnecting cables that could change the radiated signal. The single monopole antenna affixed on top of the Comb Generator radiates the reference signals. The test engineer can quickly verify his setup by putting the Comb Generator in place of the equipment under test. Then compare the data to previous test data obtained using the same setup. With this method, the test engineer can quickly detect potential problems with the test site or setup before making any other measurements.

CGC SERIES COMB GENERATORS FOR CONDUCTED EMI / EMC TESTING

The same principle that is used for verifying radiated emissions test site, can be employed to test the conducted emissions setup in an EMC test laboratory with a CGC series Comb Generator. This Comb Generator was specifically designed to test conducted emissions setups that utilizes Line Impedance Stabilization Networks (LISNs). The CGC series Comb Generator output is available on the standard three prong connector that can plug into any LISN that uses standard US 115 VAC socket to power the equipment under test. By using the Comb Generator the test engineer can quickly identify any problems with the conducted setup before making any final measurements.

Please read the Application Note AN-104 that provides more details on the Comb Generator.

 

 
CGO-501 1 1 - 1000 Radiated
CGO-505 5 5 - 1500 Radiated
CG-515 5 or 1 1 - 1500 Radiated
CGO-515 5 or 1 1 - 1500 Radiated
CGO-520 20 20 - 4500 Radiated
CGO-5100A 100 1000 - 18000 Radiated
CGO-51000 1000 1000 -34000 Radiated
CGC-510 0.1 or 0.5 0.1 - 30 Conducted
CGC-255 0.05 or 0.25 0.05 - 30 Conducted

 

Back Forward

 