The CLCI-400 is a bulk current injection probe designed for conducted immunity testing in compliance with MIL-STD-461 and RTCA DO-160 standards.
It operates across a wide frequency range of 10 kHz to 400 MHz, enabling reliable RF injection for various EMC test requirements. Go To Product Page
AH-118 is a double Ridge Guide broadband horn antenna designed to operate within the frequency range of 700 MHz to 18 GHz.
Ideal for regulatory compliance testing such as FCC, CE, MIL-STD-461, RTCA DO-160, and FDA standards. Go To Product Page
CLCI-100: Conducted Immunity Testing Probe 10 kHz to 100 MHz
The CLCI-100 is a precision bulk current injection probe engineered for conducted RF immunity testing in EMC applications. Go To Product Page
CLCE-1032 RF Current Probe
Wide Frequency Range (9 kHz–1000 MHz): The CLCE-1032 offers an ultra-wide frequency response ideal for advanced EMC testing and RF current monitoring across a broad spectrum. Go To Product Page
CLCE-438: RF Current Sensing Probe - 9 kHz to 400 MHz
Conforms to international EMC standards including CISPR 22, CISPR 32, MIL-STD-461, and RTCA DO-160, supporting a wide array of emission and immunity protocols. Go To Product Page
CLCE-332: Engineered to support cable diameters up to 32 mm, this excels in tight setups where compact wiring or limited access is a concern.
Conforms to international standards like CISPR 22, CISPR 32, MIL-STD-461, and RTCA DO-160, supporting various regulatory compliance procedures. Go To Product Page
CLCE-227: RF Current Probe, 27 mm Aperture
Used during MIL-STD-461 CS114 conducted susceptibility testing to monitor RF current flowing on cables while RF energy is injected using a bulk current injection (BCI) probe. Go To Product Page
CDN:M125E: Designed for power line conducted immunity testing per IEC/EN 61000-4-6 and CISPR 16-1-2, supporting RF injection from 150 kHz to 230 MHz.
Commonly used for consumer electronics, small industrial controllers, laboratory instruments, and medical devices with a single power conductor. Go To Product Page
CDN-AF2E : For conducted immunity testing 150 MHz to 230 MHz
Coupling/Decoupling Networks designed specifically for testing product for conducted immunity per IEC/EN 61000-4-6. The Com-Power CDN-AF2E fully complies with the requirements contained in the IEC 61000-4-6 and CISPR 16-1-2. Go To Product Page
CDN-M225E: Supports conducted immunity testing on two power conductors in accordance with IEC/EN 61000-4-6, over 150 kHz to 230 MHz.
Common in industrial power supplies, office equipment, lighting controllers, and small motor drives. Go To Product Page
CDN-M250E: Designed for high-current two-line conducted immunity testing per IEC/EN 61000-4-6, covering 150 kHz to 230 MHz.
Allows RF immunity evaluation under reduced, nominal, or full-load operating conditions up to 50 A per line, depending on the EUT and test requirements. Go To Product Page
CDN-M325E: Three-line power CDN compliant with IEC/EN 61000-4-6 and CISPR 16-1-2, supporting 150 kHz to 230 MHz testing.
Helps identify susceptibility issues that only appear when multiple phases are energized. Go To Product Page
CDN-M425E: Used when a product’s power entry must be tested as installed, with line, neutral, and protective earth present—for example, control cabinets, industrial power distribution modules, and equipment that includes auxiliary power conductors in the
Practical for immunity evaluation of industrial automation panels, PLC cabinets, machine control boxes, rack-mounted power systems, and embedded industrial equipment that must keep running while RF is coupled onto the power wiring. Go To Product Page
CDN-M525E: Five-line power CDN supporting IEC/EN 61000-4-6 conducted immunity testing across 150 kHz to 230 MHz.
Used for testing complex power configurations with multiple phases, neutral, and protective earth. Go To Product Page
CDN-C75E: Developed for conducted immunity testing on 75 Ω coaxial signal and data ports, compliant with IEC/EN 61000-4-6 and CISPR 16-1-2, enabling controlled RF disturbance coupling on coaxial interfaces.
Well suited for real-world immunity evaluation of products using 75 Ω coaxial interfaces, such as broadcast video equipment, CCTV systems, cable distribution hardware, RF receivers, instrumentation, and professional audio-video devices. Go To Product Page
CDM-USB-AE: Designed for conducted immunity testing of USB communication ports, fully compliant with IEC/EN 61000-4-6 and CISPR 16-1-2, enabling controlled RF disturbance coupling onto USB signal and power lines.
Enables manufacturers to verify that USB ports remain functional under RF disturbance conditions, ensuring compliance and reliable performance in electrically noisy environments. Go To Product Page
CDN-USB-BE: Intended for USB cables using a Type B connector on the EUT side and a Type A connector on the auxiliary equipment side, reflecting common real-world USB device-to-host configurations.
Used to inject RF common-mode disturbances onto USB cables while maintaining uninterrupted data and power communication between auxiliary equipment (such as host PCs, test controllers, or USB hubs) and the EUT. Go To Product Page
CDN-T2E: Designed for conducted immunity testing in full compliance with IEC/EN 61000-4-6 and CISPR 16-1-2, specifically for coupling RF disturbances onto one balanced unscreened pair used in communication and control interfaces.
Handles up to 40 V RF input and 2 A continuous current, allowing safe injection of specified disturbance levels during conducted immunity testing. Go To Product Page
CDN-T4E: Engineered for conducted immunity testing in accordance with IEC/EN 61000-4-6 and CISPR 16-1-2, the CDN-T4E enables controlled RF coupling onto two balanced unscreened conductor pairs used in data and communication ports.
Used to evaluate the immunity of products with multi-pair communication interfaces, including industrial Ethernet devices, networked controllers, automation equipment, and communication modules. Go To Product Page
CDN-T8E: Intended for cables with four unscreened balanced pairs, making it suitable for systems that use a standard Ethernet (RJ45) connector, where all four balanced pairs must be tested simultaneously.
Used to inject RF common-mode disturbances across all four balanced pairs of an Ethernet cable simultaneously, ensuring realistic immunity evaluation of devices that rely on full Ethernet connectivity during operation. Go To Product Page
LI-125C: LISN 25 Amps for CISPR 16 & ANSI C63.4 150 kHz to 30 MHz
The LI-220C Line Impedance Stabilization Network (LISN) provides the necessary measurement platform for performing power line conducted emissions compliance testing as required by most worldwide standards for commercial products. Go To Product Page
LI-150C: LISN equipped with 50μH inductor, used for FCC, CISPR, EN, and ANSI for the frequency range 150 kHz – 30 MHz
Suitable for single-phase, dual-phase, or DC systems; supports 3-phase setups with a second unit pair. Go To Product Page
The LI-220C Line Impedance Stabilization Network (LISN) provides the necessary measurement platform for performing power line conducted emissions compliance testing as required by most worldwide standards for commercial products.
The LI-220C includes one pair of single-conductor networks, housed together, to be installed in series with each current-carrying conductor in a single- phase, dual-phase or DC power system. A second LI-220C pair can be used to accommodate 3-phase power systems (Wye or Delta configurations). Go To Product Page
The LI-325C LISN operates over a frequency range of 10 kHz to 400 MHz. It is fully compliant with RTCA DO-160, FAA, and MIL-STD 461 standards.
A Line Impedance Stabilization Network (LISN) like the Com-Power LI-325C is used in real-world EMC testing to provide a standardized, repeatable reference impedance on the AC power line and to safely measure conducted emissions from equipment under test, ensuring that electronic products comply with regulatory limits on noise injected back into the mains supply. Go To Product Page