coupling decoupling network

CDN for USB Type B

CDN-USB-BE is part of a series of coupling/decoupling networks designed specifically for testing products for conducted immunity per IEC/EN 61000-4-6.

  • Designed for conducted immunity testing of USB communication ports, compliant with IEC/EN 61000-4-6 and CISPR 16-1-2, enabling controlled RF disturbance coupling onto USB signal and power conductors.
  • Operates over a frequency range of 150 kHz to 230 MHz, covering the full conducted RF immunity spectrum required by IEC/EN 61000-4-6.
  • Intended for USB cables using a Type B connector on the EUT side and a Type A connector on the auxiliary equipment side, reflecting common real-world USB device-to-host configurations.
  • Provides the standardized 150 Ω common-mode impedance across the specified frequency range, meeting the impedance requirements defined by IEC/EN 61000-4-6 and CISPR 16-1-2.
  • Supports up to 40 V RF input voltage and 1 A maximum current, allowing stable injection of RF disturbance levels during immunity testing of USB interfaces.
  • Equipped with a 50 Ω BNC RF input port, enabling direct connection to RF signal generators and power amplifiers used in conducted immunity test systems.
  • Constructed with a rugged metal enclosure and an unpainted base surface to ensure effective grounding and consistent performance during immunity testing.
  • Individually calibrated with NIST-traceable calibration data and a defined voltage division factor, supporting accurate, repeatable, and traceable establishment of test levels.
  • Used to inject RF common-mode disturbances onto USB cables while maintaining uninterrupted data and power communication between auxiliary equipment (such as host PCs, test controllers, or USB hubs) and the EUT.
  • Well suited for real-world immunity evaluation of USB Type B devices, including printers, laboratory instruments, industrial controllers, medical equipment, test and measurement devices, scanners, and embedded systems that rely on USB connectivity during operation.
  • Allows manufacturers to confirm that USB ports remain functional under RF disturbance conditions, helping ensure reliable product performance in electrically noisy industrial and commercial environments.
  • Integrates into complete conducted immunity test systems when used with Com-Power ADA-USB-BE shorting adapters, ADA-515-2 150 Ω to 50 Ω adapter sets, TEP-050 50 Ω terminator, appropriate attenuators or directional couplers, and Com-Power ACS series power amplifiers, providing a comprehensive solution for USB conducted immunity testing.

 

Frequently bought together

USB Type-B CDN Features:

  • Frequency range 150 MHz to 230 MHz
  • Meets CISPR 16-1-2 requirements
  • USB cables with type B connector
  • Individual calibration
  • Three Year Warranty

Specifications:

  • Product Name: Coupling Decoupling Network (CDN)
  • Compliant Test Standards: IEC / EN 61000-4-6
  • Application: USB cable with type B connector
  • Frequency Range: 150 kHz to 230 MHz
  • RF Input Voltage: 40 V (Max)
  • RF Input Connector: 50 Ω BNC (Female)
  • Voltage Rating: 30 V AC / 30 V DC (Line to Ground)
  • Current Rating: 1 Amp (Max)
  • AE and EUT Connections: EUT: Type B, AE: Type A
  • Common Mode Impedance:
    • 150 kHz - 26 MHz: 150Ω ± 20Ω
    • 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω
    • 80 MHz - 230 MHz: 150Ω + 60Ω / – 60Ω
  • Voltage Division Factor: 9.5 dB +2 / -1
  • Decoupling of Common Mode Disturbance: ≥ 50dB (EUT/AE)
  • Dimensions: 8.5 x 4.5 x 3.5 inches or 21.5 x 11.4 x 8.8 cm
  • Weight: 2 lbs. or 0.9 kg
  • Accessories Available from Com-Power for setting test levels and running the test:
    • ADA-USB-BE shorting adapters
    • ADA-515-2 150 Ω to 50 Ω adapters
    • TEP-050 50 Ω Terminator
    • ATTN-6-100W Power Attenuator
    • DCU-300-100W Directional Coupler
    • ASC series Power Amplifiers

chart chart